SONEX Rondo Sound Baffles

$576.00$1,304.00

NRC Range: 0.80 (2.43 Sabin)
Length / Ø: 24″ / 6″
SONEX Rondo Baffles offer design versatility and exceptional acoustical properties.

Baffle corkscrews and cables sold separately.

  • NRC Range: 0.80 (2.43 Sabins)
Limit of 10 boxes per order. Please call 800-662-0032 for purchases over 10 boxes.
COLORS: Colors do not necessarily reflect the actual color of the product.
SHIPPING TIME: Natural Finishes typically ship same day to 10 days, Standard Painted finishes typically 10 to 15 days and Premium Colors 15+ days.
SHIPPING RESTRICTION: Due to Proposition 65 and local building codes and regulations, polyurethane foam cannot ship into the state of California.

Easy to install vertically or horizontally, SONEX Rondo Sound Baffles are ideal for a broad range of interior spaces, including conference rooms, reception areas, libraries, production facilities and stadiums.

SONEX Rondo Baffles improve the quality of sound in any large room. SONEX Rondo Baffles are made from willtec, open cell, melamine foam and are Class 1 fire-rated according ASTM E 84 for flame spread and smoke density. SONEX Rondo Baffles may be mounted vertically or horizontally with corkscrew hangers.

Additional Information

Weight N/A
Dimensions N/A

Product Information

Physical Data
SONEX Rondo Sound Absorption Information

Size

  • Up to 24″ (610 mm) lengths
  • 6″ (152 mm) or custom diameters

Applications

  • Reception areas and conference rooms
  • Multipurpose rooms and gymnasiums
  • Aquatic centers and indoor pools
  • Music and classrooms
  • Nearly any interior space with reverberation or
    echo problems

Material

  • made from willtec® foam, which is Class 1 fire-rated according to ASTM E 84 for flame spread and smoke density.
  • Standard water-based acoustic coating color options in arctic white, ivory, beige, light blue, light, medium or dark grey, black and other premium or custom options are available

Installation

  • Can be hung vertically or horizontally, above or below ceiling lights
  • The distance between hanging absorbers and the ceiling has little effect on acoustic performance
  • Avoid hanging baffles more than 10′ below ceiling (long tethering may cause baffles to sway in areas with strong air currents)

Installation

General installation instructions

Arrange baffles in an even, balanced pattern above the area to be treated.

  • SONEX One Baffles are manufactured with integrated straps and grommets for easy installation on ceiling-mounted cables or chains.
  • SONEX Valueline and WHISPERWAVE Baffles feature corkscrew hangers that are installed in the field for either wall-to-wall cable installation or ceiling-mounted cable installation.
  • Baffle distance from the ceiling has little effect on acoustic performance. Avoid hanging baffles more than 10 feet below the ceiling because long tethering will cause them to sway in air currents.
  • Baffles can be hung horizontally or vertically, above or below the lights.

.
Wall-to-wall cable installation

For large jobs over open areas where scaffolding would be cumbersome, it is best to arrange SONEX Valueline or WHISPERWAVE Baffles parallel to each other. Optional spacers from pinta help place baffles evenly across cable span.

Ceiling-mounted cable installation

This method can be used with either SONEX Valueline, SONEX One or WHISPERWAVE Baffles. The baffles can be aligned in the same direction or arranged so that every other baffle is turned 90 degrees. Tests have shown that baffles arranged in an alternating pattern perform slightly better than baffles hung in the same direction.

Installing Corkscrew Hanger in SONEX Valueline or WHISPERWAVE Baffle

  1. Mark a dot at least 3″ in from each edge of the baffle and centered on the width of the baffle. Optimal placement is between 4″ and 8″ when hung horizontally. (download the installation instructions below for graphics)
  2. Center the corkscrew hanger over the dot. Holding the hanger vertically, press down lightly and turn. Allow the downward pressure to pierce the foam; do not poke the hanger point into the foam. If necessary, spray hanger with dry lubricant.
  3. If the hanger pops out of the side of the baffle, start over at a different point. Do not try to restart in the same place.
  4. Turn the corkscrew hanger clockwise until it is completely seated and the top coil of the hanger is touching the edge of the baffle.
  5. If doing a large installation, prepare a stack of baffles to mark hanger placement at the same time. This will speed up the process and will give a uniform look.

NOTE: Turn the eye loop so it is parallel to the top of the baffle and the opening of the eye loops face in the same direction. This is very important for the wall-to-wall cable method.

Wall-to-wall cable installation

  1. Determine length of cable needed to suspend it across the room to hang baffles. (download the installation instructions below for graphics)
  2. Attach steel cable to one wall or I-beam with eyebolts and turnbuckles.
  3. Attach the other end of the cable to the opposite wall or beam and tighten.
  4. Slip the eye loops over the cable. Turn the eye loops approx. 1/4 turn counterclockwise so the eye loops are perpendicular to the baffle, locking the cable in place.
  5. Slide baffles across the cable. Insert pinta spacers between baffles for even placement across the cable span. Spacers can be used on the ends of cables to keep baffles clear of objects, or between baffles to create openings for ductwork or light fixtures.
  6. Optional: Install a center support hook or eye in the middle of the ceiling to counter cable sag (approx. 21/2″ over 80 feet). Slide baffles from each end of the cable to the center.

.

Recommended hardware for wall-to-wall method (available from building suppliers):

  • 3/32″ (7 x 7) uncoated cable and cable clamps
  • 3/8″ eye bolt (2 per length of cable)
  • 1/8″ rope thimble cable protector (2 per length of cable)
  • 3/8″ x 31/2″ turnbuckle (1)

.

Ceiling-mounted installation

  1. Use 1/16″ cable or lightweight chain to hang baffles from the ceiling. (download the installation instructions below for graphics)
  2. Attach cable or chain from the ceiling by looping it around ceiling joists or trusses, or installing anchor eyes in the ceiling.
  3. If installing SONEX® Valueline or WHISPERWAVE Baffles, slip the eye loop of the corkscrew over the cable. Turn the eye loops approximately 1/4 turn counterclockwise so the eye loop is perpendicular to the baffle, locking the cable in place.
  4. If installing SONEX One Baffles, simply attach the bottom end of the cable or chain to the grommet in the corner of the baffle, either directly or by using “S” hooks.

.

General Characteristics

General tolerances & dimensions stability

Thickness:
– Up to 2” – tolerances of +/- 2 MM = +/- 0.08”
– Above 2” – tolerances of +/- 3 MM = +/-1/8”

Length & width:
– Up to 24” tolerance of +/- 3 MM = 1/8”
– Up to 96” tolerance of +/- 6 MM = 1/4”

Sonex convolution (sonex one / valueline / classic / mini / junior):
– Pattern alignment to edge: +/-1”

Due to the nature of willtec material, temperature and humidity may cause dimensional changes of up to 4% by volume.

Color Chart

Natural WILLTEC®

white

grey

Coated WILLTEC®

arctic white

medium grey

light grey

black

COLORTEC®

black*

*Color is impregnated in the foam and has a water-based acoustic coating on top.

Premium HPC Paint Colors

Vermillion

Vermillion

Orange Red

Orange Red

Frost

Frost

Superior

Superior

Olive

Olive

Yellow

Sweet Corn

Black

Brown Black

Dark Grey

A minimum order of five boxes is required for premium colors.

Polyurethane

Polyurethane brown

brown

Polyurethane charcoal

charcoal

SKU: N/A Category: Tags: ,
Updating…
  • No products in the cart.